The simulated sensor data are injected as a data stream during the measurement cycle.
The injection can be done in three different ways:
Manually
The stream data package is injected by clicking on the button
.
Automatical
The stream data package is injected automatic in the defined repetition rate after the initphase.
External pin wiring
The stream data package is injected by a wiring of an input pin.
The setting is done at the Bus-Configuration window section Settings.
|
Settings |
Section of the BUS-Configuration window |
||
|---|---|---|---|
| Application Layer | ![]() |
||
| StreamReplayCount |
Repetition rate of the sensor data stream |
Directly input |
|
| StreamSampleTime |
Duration of the sensor data stream |
Directly input |
|
| StreamStartMode | Definition of the sensor data resource |
Manual = Start by the button Stream start Automatic = Automatically injection with defined repetition rate ExternalPin = Injection via input pin. |
|