Master data window description

masterdatapat.jpg

 

By selection of the command all mandatory fields will be refilled and can be modified individually.

 

Column

Description

No Automatic generated increasing number of the position of the single commands.

Command

Selection of the master command (Description) from the displayed list.
Address Address of the sensors in hexadecimal format.
CMD/Extdata/Data/CRC Structure of the data package of the ECU at CR mode by direct input in hexadecimal format.
Value Hexadecimal value of the complete data package.
BitCount

Number of bits of the complete data package.

Comment Freely edible, textual description for comfortable overview
Buttons and option fields
Add Insert an empty command line at the end of the command list.
Delete Deletes a marked command line. The mark is done by clicking on the desired line.
Insert Insert a new command line above the marked command line..
If the option field
Copy Data is activated, the marked line will be copied and inserted.
If the option field Copy Data is deactivated, an empty line will be inserted.
Copy data Activated = Copies the marked line during the command Insert.
Deactivated = Insert an empty line during the command Insert.
Save Saves the master data command list as txt format.
Load Load a master data command line, which was saved as txt format.