Master data commands

The following commands for master data definition are available:

 

Command

Description

CR

Input of the  Command and Response data package. The available commands are sensor specified and have to be defined corresponding to the sensor manufacturer data sheet.

CR_Write Command and Response package with  "write" command
CR_Read Command and Response Package with  "read" Command
PD Periodic Data Collection Mode package
BG Background Diagnostic Mode package
CR_CRC

Command and Response package with  explicit CRC declaration
(at all other commands the CRC value will be automatically computed)

BG_CRC

Background Diagnostic Mode Packet, with explicit CRC declaration
(at all other commands the CRC value will be automatically computed)

Loop Loop command to the defined entry
Field Value = Number of loops
Field Bitcount = Loop index
Delay Time delay in µs after command execution
Discovery Discovery mode will be initialized
Power Power voltage on/off
Exit Stop of the master data execution