The following commands for master data definition are available:
Command |
Description |
CR |
Input of the Command and Response data package. The available commands are sensor specified and have to be defined corresponding to the sensor manufacturer data sheet. |
CR_Write | Command and Response package with "write" command |
CR_Read | Command and Response Package with "read" Command |
PD | Periodic Data Collection Mode package |
BG | Background Diagnostic Mode package |
CR_CRC |
Command and Response package with explicit CRC declaration |
BG_CRC |
Background Diagnostic Mode Packet, with explicit CRC declaration |
Loop | Loop command to the defined entry Field Value = Number of loops Field Bitcount = Loop index |
Delay | Time delay in µs after command execution |
Discovery | Discovery mode will be initialized |
Power | Power voltage on/off |
Exit | Stop of the master data execution |