Parameter bus configuration

Bus configuration

Section of the

BUS configuration window

ConstantLength

Constant time lap of a transmission cycle.
Missing time will generate by filling with pause impulse.

Direct value entry in µs

par_bus.jpg

CRCMode

Kind of CRC generation by selection at the displayed list.

StandardNew

StandardLegacy

SpcNew

SpcLegacy

DataHighLevel

Voltage level of the data signal.

Direct value entry in V

DataTriggerLevel

Voltage level from which the voltage change will be recognized.

Direct value entry in V

FallTime

Time lap of the voltage change from High to Low

Direct value entry in µs

 

MessageLength

Length of the transmission including the CRC without the synchronization in ticks

Direct value entry in ticks

PullUp

Selection of the voltag line of the pullup resistors

_33V=to 3,3V line

_5V=to 5V line

_VDD1=to  VDD1 line

_VDD2= to VDD2-line

RiseTime

Time lap of the voltage change from Low to High

Direct value entry in µs

 

SupplyVoltage

Supply voltage

Direct value entry in V