Each single sensor signal will be generated internally or externally.
Internal:
Generation of a signal according to the defined sensorsignal parameter.
Setting parameter of the internal sensor data generation.
| Procedure | |
|
|
Open the BUS Configuration window. |
|
|
At the section SENT-Sensor set the parameter External to False by clicking into the field and select from the displayed selection list. |
|
|
Set the parameter Source at the according defined slot to 0 |
External:
An external sensor signal can be injected via the 25-pol. Analog I/O-interface either as:
a signal via the inputs A0, A1, A2, A3 (-10 V ... + 10 V), 12 bit altered.
Input A0 Parameter Source=1
Input A1 Parameter Source=2
Input A2 Parameter Source=3
Input A3 Parameter Source=4
as a stream data package
Parameter Source=5
as raw data stream.
Parameter Source=6
Constant 0-signal
Parameter Source=7
|
Procedure |
|
|
|
Open the BUS Configuration window. |
|
|
At the section SENT-Sensor set the parameter External to True by clicking into the field and select from the displayed selection list. |
|
|
Set the parameter Source at the according defined slot to the number of the analog input. |