PSI5-BUS-Parameter

The specific BUS parameters are defined according to the chosen operating system.

 

PSI5- A / P / U / D / V dd P/CRC-tttt/n,L/H (Syntax of the BUS configuration)

 

Operating mode

 

A

Asynchron Modus

 

P

Synchron Parallel Modus

 

U

Synchron universal

 

D

Synchron Daisy Chain

 

V

Variable triggered
Synchronous mode

 

Number of data bits

 

dd

Decimal 2-digit(08 or 24)

8, 10, 16, 20 und 24 bit data length.

Error detection

 

P

Paritiy - Error

Creation/testing.

 

CRC

CRC - Error

Cycle time in µs

 

tttt

Decimal (for example 500)

 

Number of time slots per cycle time

 

n

(only in synchronous mode of the ECU operating system)

Decimal

1 to 4.The number of possible timeslots depends on the baud rate and the distance between the Sync-impulses.

 

Baudrate

 

L

125 kbps

Settings are possible from 100 kbit/s to 250 kBit/s in steps of 208 bit/s (@100 kbit/s) and 1295 bit/s (@250kbit/s) especially 125kbit/s and 189kbit/s.
The baud rate departs at a value of 189kbit/s with -0,0125%.

H

189 kbps

Additional parameter settings in the Simulyzer

Distance of the Sync-impulses

Available in the ECU operating system in the interval from 250 µs to
5 ms/solution 1 µs

Duration of the sync-impulse amplitude
(only in synchronous mode of the ECU operating mode)

Available from 5 µs to
100 µs / solution 1 µs.

 

Value of the Sync-impulse voltage
(only in synchronous mode of the ECU operating mode)

Available from 0 V to
12 V via USB
with optional external supply 0 V to 20 V.

Location of  Timeslots
(only in synchronous mode)

In the framework of the Sync-impulse distance available/ solution 1 µs

Distance of the data packets

(only in asynchronous mode of the SensorSim operating mode)

Available in the interval from 50 µs to 10 ms/

solution 1 µs

Value of the supply voltage
(only in the ECU operating mode)

Available from 0 V to 12 V via USB
with optional external supply 0 V to 20 V.

Logic electricity barrier

Manchester Code 5,0 mA to 50,0 mA

Logic voltage barrier

Sync-impulses 0 V to 28 V

 

Example:

PSI5-P10P-500-4H

Parallel synchronous mode with 10 bit data word length, parity error detection

500 µs cycle time, 4 data slots with a speed of 189 kbps.

 

The Simulyzer offers a lot of predefined definitions of the BUS-parameters

which are saved as projects in the corresponding syntax.

You can find detailed information of the PSI5-Bus-spezifications at http://www.psi5.org/en/en/psi5/home/index.aspx.